| Product | Description |
|---|---|
| RTP 200 | Unreinforced Base Resin (Precolor Only) |
| RTP 201 | Glass Fiber 10% |
| RTP 202 | Glass Fiber 15% |
| RTP 203 | Glass Fiber 20% |
| RTP 205 | Glass Fiber 30% |
| RTP 207 | Glass Fiber 40% |
| RTP 209 | Glass Fiber 50% |
| RTP 211 | Glass Fiber 60% |
| Search by mechanical properties Side-by-side material comparisons Visit data.rtpcompany.com | |
| VLF 80205 EM HS | Long Glass Fiber 30% - Easy Molding - Heat Stabilized |
| VLF 80207 EM HS | Long Glass Fiber 40% - Easy Molding - Heat Stabilized |
| VLF 80209 EM HS | Long Glass Fiber 50% - Easy Molding - Heat Stabilized |
| VLF 80211 EM HS | Long Glass Fiber 60% - Easy Molding - Heat Stabilized |
| RTP 200 AR 15 | Aramid Fiber 15% |
| RTP 200 AR 20 | Aramid Fiber 20% |
| RTP 200 AR 10 TFE 10 | Aramid Fiber 10% - PTFE 10% |
| RTP 200 AR 15 TFE 10 | Aramid Fiber 15% - PTFE 10% |
| RTP 200 AR 15 TFE 15 | Aramid Fiber 15% - PTFE 15% |
| RTP 200 AR 15 TFE 15 SI 2 | Aramid Fiber 15% - PTFE 15% - Silicone 2% |
| RTP 200 FR | Flame Retardant - UL94 V-0 |
| RTP 200.5 FR | Glass Fiber 5% - Flame Retardant - UL94 V-0 |
| RTP 201 FR | Glass Fiber 10% - Flame Retardant - UL94 V-0 |
| RTP 202 FR | Glass Fiber 15% - Flame Retardant - UL94 V-0 |
| RTP 203 FR | Glass Fiber 20% - Flame Retardant - UL94 V-0 |
| RTP 204 FR | Glass Fiber 25% - Flame Retardant - UL94 V-0 |
| RTP 205 FR | Glass Fiber 30% - Flame Retardant - UL94 V-0 |
| RTP 207 FR | Glass Fiber 40% - Flame Retardant |
| RTP 200 FR NH | Flame Retardant - Halogen Free |
| RTP 200 FR UV | Flame Retardant - UV Stabilized |
| RTP 201 FR UV | Glass Fiber 10% - Flame Retardant - UV Stabilized - UL94 V-0 |
| RTP 203 FR UV | Glass Fiber 20% - Flame Retardant - UV Stabilized |
| RTP 204 FR UV | Glass Fiber 25% - Flame Retardant - UV Stabilized |
| RTP 205 FR UV | Glass Fiber 30% - Flame Retardant - UV Stabilized |
| RTP 200 GB 20 | Glass Bead 20% |
| RTP 200 GB 40 | Glass Bead 40% |
| RTP 202 GB 25 | Glass Fiber 15% - Glass Bead 25% |
| RTP 204 GB FR | Glass Bead 25% - Flame Retardant - UL94 V-0 |
| RTP 200 GB 20 HS | Glass Bead 20% - Heat Stabilized |
| RTP 200 GB 30 HS | Glass Bead 30% - Heat Stabilized |
| RTP 200 GB 15 TFE 15 | Glass Bead 15% - PTFE 15% |
| RTP 203 HB | Glass Fiber 20% - UL94 HB |
| RTP 205 HB | Glass Fiber 20% - UL94 HB |
| RTP 207 HB | Glass Fiber 20% - UL94 HB |
| Search by mechanical properties Side-by-side material comparisons Visit data.rtpcompany.com | |
| RTP 200 HS MS 2 | Molybdenum Disulfide 2% - Heat Stabilized |
| RTP 205 HS MS 2 | Glass Fiber 30% - Molybdenum Disulfide 2% - Heat Stabilized |
| RTP 205 HS MS 5 | Glass Fiber 30% - Molybdenum Disulfide 5% - Heat Stabilized |
| RTP 200 MS 2 | Molybdenum Disulfide 2% |
| RTP 200 MS | Molybdenum Disulfide 4% - UL94 HB |
| RTP 200 MS Natural | Molybdenum Disulfide 4% |
| RTP 200 MS 5 | Molybdenum Disulfide 5% |
| RTP 203 MS | Glass Fiber 20% - Molybdenum Disulfide 4% |
| RTP 203 MS 5 | Glass Fiber 20% - Molybdenum Disulfide 5% |
| RTP 205 MS 2 | Glass Fiber 30% - Molybdenum Disulfide 2% |
| RTP 205 MS | Glass Fiber 30% - Molybdenum Disulfide 4% |
| RTP 205 MS 5 | Glass Fiber 30% - Molybdenum Disulfide 5% |
| RTP 207 MS | Glass Fiber 40% - Molybdenum Disulfide 4% |
| RTP 201 MS 2 HB | Glass Fiber 10% - Molybdenum Disulfide 2% - UL94 HB |
| RTP 209 MS UV | Glass Fiber 50% - Molybdenum Disulfide 4% - UV Stabilized |
| RTP 200 SE | Self Extinguishing - UL94 - All Colors |
| RTP 200 SI 2 | Silicone 2% |
| RTP 205 SI 2 | Glass Fiber 30% - Silicone 2% |
| RTP 299 X 83820 B | Fluoroguard® <1% |
| RTP 299 X 93636 B | Fluoroguard® <1% - PTFE <5% |
| RTP 200 TFE 5 | PTFE 5% |
| RTP 200 TFE 10 | PTFE 10% |
| RTP 200 TFE 15 | PTFE 15% |
| RTP 200 TFE 20 | PTFE 20% |
| RTP 200 TFE 20 FR | PTFE 20% - Flame Retardant |
| RTP 200 TFE 20 HS | PTFE 20% - Heat Stabilized |
| RTP 200 TFE 5 SI 2 | PTFE 5% - Silicone 2% |
| RTP 200 TFE 10 SI 2 | PTFE 10% - Silicone 2% |
| RTP 200 TFE 18 SI 2 | PTFE 18% - Silicone 2% |
| RTP 200 TFE 20 SI | PTFE 20% - Silicone 0.5% |
| RTP 200 TFE 18 SI 2 HB | PTFE 18% - Silicone 2% - UL94 HB |
| RTP 200 TFE 5 Z | PTFE 5% - FDA Compliant Ingrediants |
| RTP 203 TFE 5 | Glass Fiber 20% - PTFE 5% |
| RTP 203 TFE 10 | Glass Fiber 20% - PTFE 10% |
| RTP 203 TFE 15 | Glass Fiber 20% - PTFE 15% |
| RTP 203 TFE 20 | Glass Fiber 20% - PTFE 20% |
| RTP 205 TFE 5 | Glass Fiber 30% - PTFE 5% - UL94 HB |
| RTP 205 TFE 10 | Glass Fiber 30% - PTFE 10% |
| RTP 205 TFE 15 | Glass Fiber 30% - PTFE 15% |
| RTP 205 TFE 20 | Glass Fiber 30% - PTFE 20% |
| RTP 205.3 TFE 15 | Glass Fiber 33% - PTFE 15% |
| RTP 206 TFE 15 | Glass Fiber 35% - PTFE 15% |
| RTP 207 TFE 10 | Glass Fiber 40% - PTFE 10% |
| RTP 203 TFE 15 FR | Glass Fiber 20% - PTFE 15% - Flame Retardant |
| RTP 205 TFE 15 FR | Glass Fiber 30% - PTFE 15% - Flame Retardant |
| RTP 203 TFE 20 HB | Glass Fiber 20% - PTFE 20% - UL94 HB |
| RTP 205 TFE 15 HB | Glass Fiber 30% - PTFE 15% - UL94 HB |
| RTP 205 TFE 15 HS | Glass Fiber 30% - PTFE 15% - Heat Stabilized |
| RTP 203 TFE 13 SI 2 | Glass Fiber 20% - PTFE 13% - Silicone 2% |
| RTP 205 TFE 13 SI 2 | Glass Fiber 30% - PTFE 13% - Silicone 2% |
| RTP 205 TFE 15 SI | Glass Fiber 30% - PTFE 15% - Silicone 0.5% |
| RTP 205 TFE 15 SI 2 | Glass Fiber 30% - PTFE 15% - Silicone 2% |
| RTP 205 TFE 15 UV | Glass Fiber 30% - PTFE 15% - UV Stabilized |
| RTP 205 TFE 15 Z | Glass Fiber 30% - PTFE 15% - FDA Compliant |
| RTP 201 UV | Glass Fiber 10% - UV Stabilized |
| RTP 206 UV | Glass Fiber 35% - UV Stabilized |
| Search by mechanical properties Side-by-side material comparisons Visit data.rtpcompany.com | |
| RTP 225 | Mineral 20% |
| RTP 227 | Mineral 40% |
| RTP 227 FR | Mineral 40% - Flame Retardant |
| RTP 227 MS | Mineral 40% - Molybdenum Disulfide 4% |
| RTP 299 X 97771 B | 3M™ Scotchlite™ Glass Bubbles |
| RTP 281 | Carbon Fiber 10% |
| RTP 282 | Carbon Fiber 15% |
| RTP 283 | Carbon Fiber 20% |
| RTP 285 | Carbon Fiber 30% |
| RTP 287 | Carbon Fiber 40% |
| RTP 289 | Carbon Fiber 50% |
| RTP 291 | Carbon Fiber 60% |
| RTP 281 FR | Carbon Fiber 10% - Flame Retardant |
| RTP 283 FR | Carbon Fiber 20% - Flame Retardant |
| RTP 285 FR | Carbon Fiber 30% - Flame Retardant |
| RTP 281 MS | Carbon Fiber 10% - Molybdenum Disulfide 4% |
| RTP 281 TFE 10 | Carbon Fiber 10% - PTFE 10% |
| RTP 281 TFE 20 | Carbon Fiber 10% - PTFE 20% |
| RTP 283 TFE 15 | Carbon Fiber 20% - PTFE 15% |
| RTP 285 TFE 5 | Carbon Fiber 30% - PTFE 5% |
| RTP 285 TFE 15 | Carbon Fiber 30% - PTFE 15% |
| RTP 287 TFE 15 | Carbon Fiber 40% - PTFE 15% |
| RTP 283 TFE 15 SI 2 | Carbon Fiber 20% - PTFE 15% - Silicone 2% |
| RTP 285 TFE 13 SI 2 | Carbon Fiber 30% - PTFE 13% - Silicone 2% |
| RTP 283 HEC | Nickel-Coated Carbon Fiber 20% - EMI/RFI/ESD Protection |
| Search by mechanical properties Side-by-side material comparisons Visit data.rtpcompany.com | |
| PermaStat® 200 | Permanently Anti-static/All Polymeric |
| ESD A 200 | Static Dissipative |
| ESD A 201 | Static Dissipative - Glass Fiber 10% |
| ESD A 205 | Static Dissipative - Glass Fiber 30% |
| ESD A 280 | Static Dissipative - Carbon Fiber |
| ESD A 280 FR | Static Dissipative - Carbon Fiber - Flame Retardant |
| ESD C 200 | Electrically Conductive |
| ESD C 202 | Electrically Conductive - Glass Fiber 15% |
| ESD C 203 | Electrically Conductive - Glass Fiber 20% |
| ESD C 205 | Electrically Conductive - Glass Fiber 30% |
| ESD C 205 UV | Electrically Conductive - Glass Fiber - UV Stabilized |
| ESD C 280 | Electrically Conductive - Carbon Fiber |
| ESD C 280 FR | Electrically Conductive - Carbon Fiber - Flame Retardant |
| EMI 260.5 | EMI/RFI Shielding - Stainless Steel Fiber 5% |
| EMI 261 | EMI/RFI Shielding - Stainless Steel Fiber 10% |
| EMI 262 | EMI/RFI Shielding - Stainless Steel Fiber 15% |
| EMI 263 | EMI/RFI Shielding - Stainless Steel Fiber 20% |
| Additional Data for Select Compounds |
|---|
| Shielding Effectiveness Data |
| Tensile Stress/Strain & Bi-Directional Design Data |
| Wear Factor Data |