PAGE CONTENTS    (Navigation)

RTP 400 to 900 Series UL Recognized compounds

The following RTP Company thermoplastic compounds are recognized under the Component Recognition Program of Underwriters Laboratories, Inc. As such, their flammability has been rated based on tests conducted by UL. These rating are only valid at a thickness equal to or greater than that indicated in these listings.

Yellow Cards for our products Recognized by UL are on file only for the compounds listed in this section. Other RTP Company compounds, listed elsewhere on our website, may be assigned a flammability rating based on independent testing done by RTP Company. These ratings are for descriptive purposes only.

If you require UL Recognition for a compound not listed in this section, RTP Company can assist you with submitting that compound to UL for testing.

NC
Product Color Thickness Flame
Class
Relative Thermal Index H
W
I
H
A
I
H
V
T
R
D
4
9
5
C
T
I
Inch mm Elect Mech
w/ imp
Mech
w/o imp
RTP 401 FR All 1/16 1.57 V-0 50 50 50          
RTP 499 X 50246 All 1/16 1.57 V-0 50 50 50          
RTP 499 X 61952 A BK 1/16 4.17 HB 50 50 50          
RTP 499 X 105641 All 1/16 1.50 HB 50 50 50          
 
RTP 500.5 HB thru
RTP 507 HB (b)
All 1/16 1.57 HB 50 50 50          
RTP 501 FR All 1/32 0.79 V-0 50 50 50          
RTP 503 FR All 1/32 0.79 V-0 50 50 50          
RTP 505 FR All 1/32 0.79 V-0 50 50 50          
RTP 506 FR All 1/32 0.79 V-0 50 50 50          
 
RTP 600 FR AB All 1/16 1.50 V-0 60 60 60          
All 1/8 3.00 V-0 60 60 60          
RTP 600 FR AU All 1/16 1.50 V-0 60 60 60          
All 1/8 3.00 V-0 60 60 60          
RTP 600 FR AW All 1/16 1.50 V-0 60 60 60          
All 1/8 3.00 V-0 60 60 60          
RTP 600 HB
RTP 600 Z HB
All 1/16 1.47 HB 60 60 60          
RTP 600 TFE 10 HB All 1/16 1.50 HB 60 60 60          
RTP 600 TFE 10 FR NC 1/16 1.62 V-0 60 60 60          
RTP 600 SI 2 HB All 1/16 1.50 HB 60 60 60          
RTP 601 FR thru
RTP 605 FR; (q)
All 1/16 1.50 V-0 60 60 60          
All 1/8 3.00 V-0 60 60 60          
RTP 681 HB
thru RTP 687 HB (a)
NC 1/16-1/8 1.47-6.05 HB 60 60 60          
RTP 687 HB NC 1/16 1.47 HB 60 60 60          
RTP 699 X 68860 U All 1/16 1.50 V-0 60 60 60          
All 0.085 2.15 V-0 60 60 60          
All 1/8 3.00 V-0 60 60 60          
RTP 699 X 69676 All 1/16 1.47 HB 60 60 60          
RTP 699 X 76978 WT 0.050 1.30 HB 60 60 60          
RTP 699 X 85278 B BK 1/16 1.50 V-0 60 60 60          
BK 1/8 3.00 V-0 60 60 60          
RTP 699 X 92308 BK 1/16 1.50 HB 60 60 60          
RTP 699 X 100192 All 1/16 1.40-1.07 V-0 60 60 60          
RTP 699 X 110718 BK 1/8 3.00-3.30 V-0 60 60 60          
RTP 0699 X 115624 A NC,BK 1/16 1.50 HB 60 60 60          
PermaStat® 600 FR All 1/16 1.47 V-0 60 60 60          
 
RTP 800 TFE 5 HB NC, BK 1/16 1.50 HB 50 50 50          
RTP 800 TFE (p) SI 2 HB NC, BK 1/16 1.50 HB 50 50 50          
RTP 800 SI 2 HB All 1/32 0.76 HB 50 50 50          
RTP 800 TFE 5 DEL S-92306 BN 1/16 1.47 HB 50 50 50          
RTP 800 TFE 20 DEL S-92306 BN 1/16 1.47 HB 50 50 50          
RTP 805 SI 2 HB 1/16 1.47 HB 50 50 50          
RTP 881 HB NC (nat/blk) 1/16 1.5 HB 50 50 50          
RTP 899 X 72560 NC, BK 1/16 1.50 HB 50 50 50          
RTP 899 X 74932 B NC, BK 1/16 1.50 HB 50 50 50          
RTP 899 X 88199 All 1/16 1.50 HB 50 50 50          
RTP 899 X 115652 All 1/16 1.50 HB 50 50 50          
RTP 899 X 115692 NC, BK 1/16 1.50 HB 50 50 50          
ESD 800 HB BK 1/16 1.50 HB 50 50 50          
RTP 899 X 93924 All 1/32 0.75 HB 50 50 50          
 
RTP 900 P-1700 NC 0.020 0.51 - 160 140 160          
NC 1/16 1.47 HB 160 140 160 3 4 4    
All 1/16 1.57 HB 160 140 160 3 4 4    
NC 1/8 3.05 HB 160 140 160 1 4   7 4
NC 0.175 4.47 V-0 160 140 160          
NC 1/4 6.10 V-0 160 140 160 1 3 2    
RTP 900 P-1720 NC 0.020 0.51 - 160 140 160          
NC 0.040 1.02 V-1 160 140 160          
NC 1/16 1.47 V-0 160 140 160 4 4 4    
All 0.075 1.91 V-0 160 140 160          
All 1/8 3.05 V-0 160 140 160 3 3 3 6 4
All 1/4 6.10 V-0 160 140 160 1 3 3    
RTP 900 P-3500 NC 0.020 0.51 - 160 140 160          
NC 1/8 3.05 - 160 140 160 2   2   4
NC 1/4 6.10 - 160 140 160 1   2    
RTP 900 GF-110
RTP 900 GF-120
All 1/16 1.57 HB 160 140 160 3 4      
All 1/8 3.05 HB 160 140 160 1 4   7 4
All 0.175 4.47 V-0 160 140 160          
All 1/4 6.10 V-0 160 140 160          
RTP 900 GF-130 NC 1/32 0.78 V-2 50 50 50 1 4      
All 1/16 1.57 V-1 160 140 160 1 4      
All 1/8 3.17 V-0 160 140 160 1 4 4 5 4
RTP 900 M-825 All 1/16 1.50 V-2 155 140 155 2 4 1    
All 1/8 3.00 V-0 155 140 155 1 4 1 5 3
RTP 901 UV (f2) All 1/16 1.47 V-1 50 50 50 2 1      
All 1/8 3.05 V-0 50 50 50 1 1     4
RTP 903RTP 903 SC-22548 WH 1/16 1.47 HB 50 50 50          
RTP 905 (f1) All 1/8 3.00-3.20 V-0 50 50 50          
All 1/8 3.00-3.20 5V-A 50 50 50          
Product Color Inch mm Flame
Class
Elect Mech
w/ imp
Mech
w/o imp
H
W
I
H
A
I
H
V
T
R
D
4
9
5
C
T
I
Thickness Relative Thermal Index

PermaStat® is a registered trademark of RTP Company

Notes:

  • (a) = the last digit can be replaced with any integer from 1 - 7.
  • (b) = the last digit can be replaced with any number from 0.5 - 7.
  • (c) = the last digit can be replaced with any number from 0 - 5..
  • (d) = "y" may be omitted or replaced with the letter "C".
  • (e) = the last digit can be replaced with any integer from 0 - 2.
  • (f1) = certified for outdoor use with respect to exposure to UV light, water exposure and immersion in accordance with UL746C.
  • (f2) = certified for outdoor use with respect to one or more of the following tests: UV, water exposure or immersion in accordance with UL746C.
  • (g) = the last digit can be replaced with any number from 0.5 - 3.
  • (h) = the last digit can be replaced with any number from 0 - 3.
  • (i) = the last digit can be replaced with any number from 0 - 2.
  • (j) = the letter can be replaced with any letter from A to G.
  • (K) = represents a single letter A-I inclusive.
  • (l) = represents a single number within the range of 5-15.
  • (m) = the letter may be replaced with any letter from C to F, which represent the corresponding LGF levels: C=30%, D=35%, E=40%, F=45%.
  • (n) = the letter should be replaced with a number, 5 - 10, inclusive.
  • (o) = the letter should be replaced with a number from the following set: [3, 3.1,3.2, 3.3, 3.4, 4, 4.1, 4.2, 4.3, 4.4, 5].
  • (p) = the letter should be replaced with a number, 5 - 20, inclusive.
  • (q) = the letter should be replaced with a number, 1 - 5, inclusive.
  • (+) = UL will allow up to 50% regrind in this product
  • ($) = Represents all colors except blue and green.

Copies of UL Yellow Cards for RTP Company compounds listed in this section are available via fax or postal mail upon request. Contact our Marketing Communications staff at 507-454-6900 or 800-433-4787, fax 507-454-2041, or e-mail rtp@rtpcompany.com.