PAGE CONTENTS    (Navigation)

RTP 3400 to 4700 Series UL Recognized compounds

The following RTP Company thermoplastic compounds are recognized under the Component Recognition Program of Underwriters Laboratories, Inc. As such, their flammability has been rated based on tests conducted by UL. These rating are only valid at a thickness equal to or greater than that indicated in these listings.

Yellow Cards for our products Recognized by UL are on file only for the compounds listed in this section. Other RTP Company compounds, listed elsewhere on our website, may be assigned a flammability rating based on independent testing done by RTP Company. These ratings are for descriptive purposes only.

If you require UL Recognition for a compound not listed in this section, RTP Company can assist you with submitting that compound to UL for testing.

Product Color Thickness Flame
Class
Glow Wire Rating Relative Thermal Index H
W
I
H
A
I
H
V
T
R
D
4
9
5
C
T
I
Inch mm GWIT GWFI Elect Mech
w/ imp
Mech
w/o imp
RTP 3400 FC-110 NC 0.019 0.49 V-0     220 220 220          
All 1/16 1.57 V-0     240 220 240 1 3      
All 1/8 3.18 V-0     240 220 240 1 3 0 5 4
RTP 3400 FC-130 All 1/32 0.79 V-0     220 240 220          
All 1/16 1.57 V-0     240 240 240 0 3      
All 1/8 3.18 V-0     240 240 240 0 3 0 3 3
RTP 3400 G-330 BK 1/32 0.75 V-0     220 200 220          
NC 0.034 0.87 V-0     220 200 220 3 4      
BK 1/16 1.50 5VA     220 200 220          
BK, NC 1/16 1.50 V-0     220 200 220 2 4      
BK,NC 1/8 3.00 V-0     240 200 240 1 4 0 5 3
RTP 3400 G-345 NC 0.021 0.54 V-0     130 130 130          
BK 1/32 0.75 V-0     130 130 130   4      
BK 0.036 0.91 V-0     130 130 130 2 4      
BK 1/16 1.60 V-0     130 130 130 2 4      
BK 1/8 3.00 V-0     130 130 130 1 4 0 5 3
RTP 3400 G-430 BL 1/32 0.73 V-0     130 130 130          
BK 1/32 0.75 V-0     130 130 130   4      
NC 0.034 0.87 V-0     130 130 130 3 4      
NC 1/16 1.50 5VA     130 130 130          
NC 1/16 1.60 V-0     130 130 130 1 4      
NC 1/8 3.00 V-0     130 130 130 1 4 0 4 3
RTP 3400 G-445 BK 1/32 0.75 V-0     130 130 130   4      
NC 0.034 0.87 V-0     130 130 130 3 4      
BK, NC 1/16 1.50 V-0     130 130 130 1 4      
BK, NC 1/8 3.00 V-0     130 130 130 1 2 0 4 3
NC 1/16 1.60 5VA     130 130 130          
RTP 3400 MG-350 BK, NC 1/32 0.75 V-0     240 220 240          
BK, NC 0.035 0.89 V-0     240 220 240 3 0      
BK, NC 1/16 1.50 V-0     240 240 240 1 1      
BK, NC 1/8 3.00 V-0     240 240 240 1 0 0 4 3
RTP 3400 MG-450 BK 1/32 0.75 V-0     130 130 130   4      
BK 0.036 0.91 V-0     130 130 130 2 4      
NC 1/16 1.60 V-0     130 130 130 1 4      
NC 1/8 3.00 V-0     130 130 130 0 4 0 4 3
RTP 3400 RC-210 NC 0.019 0.49 V-0     220 220 220     0    
All 1/16 1.57 V-0     240 220 240 1 3      
All 1/8 3.18 V-0     240 220 240 1 3   5 4
RTP 3400 RC-220 NC 0.020 0.50 V-0     220 240 220          
BK 1/32 0.81 V-0     220 240 220          
BK, NC 1/16 1.50 V-0     240 240 240 1 3      
BK, NC 1/8 3.00 V-0     240 240 240 1 3 1 7 3
RTP 3405-4 BK, NC 0.012 0.30 V-0     130 130 130          
BK, NC 1/16 1.50 V-0     130 130 130          
RTP 3407-4 BK, NC 0.012 0.30 V-0     130 130 130          
BK, NC 1/16 1.50 V-0     130 130 130          
RTP 3499 X 78010 BK 1/8 3.00-3.30 V-0     130 130 130          
BK 1/8 3.00-3.30 5V-A     130 130 130          
RTP 3499-4 X 92146 BK 1/16 1.40-1.70 V-0     130 130 130          
BK 1/16 1.40-1.70 5V-A     130 130 130          
RTP 3499-3 X 106461 NC 1/32 0.74-0.76 V-0     130 130 130          
 
RTP 4005 SI 2 HB BK 1/16 1.50 HB     50 50 50          
RTP 4099 X 66014 D All 1/16 1.47 HB     50 50 50          
 
RTP 4207 BK, NC 1/16 1.40 V-0     50 50 50          
RTP 4299 X 65690 BK, NC 1/16 1.40 V-0     50 50 50          
 
RTP 4300 S-1000 NC 1/16 1.50 V-1     105 105 105 2 0      
NC 0.134 3.40 V-0     105 105 105 1 0 2 5 3
RD 1/16 1.50 V-1     105 105 105          
RD 1/8 3.00 V-0     105 105 105          
BK 1/16 1.50 HB     105 105 105          
BK 1/8 3.00 V-1     105 105 105          
All 0.134 3.40 V-2     105 105 105          
RTP 4300 S-1010 NC 1/16 1.57 V-1     50 50 50 2 2      
RTP 4300 S-1020 WT 1/16 1.50 V-2     50 50 50          
  1/8 3.00 V-0     50 50 50          
 
RTP 4600 EA 534 All 1/32 0.75 V-2 - - 50 50 50 4 0      
All 0.040 1.00 V-0 750 750 50 50 50 - -      
All 1/16 1.50 V-0 - - 125 120 120 - -      
NC, BK 0.080 2.00 5V-A - - 125 120 120 - -      
All 0.080 2.00 V-0 800 800 125 120 120 - -      
All 1/8 3.00 V-0/5V-A 825 850 125 120 120 1 0 0 7 3
 
RTP 4705 FR All 1/32 0.80 V-0     50 50 50          
All 1/16 1.50 V-0, 5V-A     50 50 50          
All 1/8 3.00 V-0, 5V-A     50 50 50          
Product Color Inch mm Flame
Class
GWIT GWFI Elect Mech
w/ imp
Mech
w/o imp
H
W
I
H
A
I
H
V
T
R
D
4
9
5
C
T
I
Thickness Glow Wire Rating Relative Thermal Index

PermaStat® is a registered trademark of RTP Company

Notes:

  • (a) = the last digit can be replaced with any integer from 1 - 7
  • (b) = the last digit can be replaced with any number from 0.5 - 7
  • (c) = the last digit can be replaced with any number from 0 - 5
  • (d) = "y" may be omitted or replaced with the letter "C"
  • (e) = the last digit can be replaced with any integer from 0 - 2
  • (f1) = subject for outdoor use with respect to exposure to UV light, water exposure and immersion in accordance with UL746C
  • (f2) = subjected to one or more of the following tests: UV, water exposure or immersion in accordance with UL746C
  • (g) = the last digit can be replaced with any number from 0.5 - 3
  • (h) = the last digit can be replaced with any number from 0 - 3
  • (i) = the last digit can be replaced with any number from 0 - 2
  • (j) = the letter can be replaced with any letter from A to G
  • (K) = represents a single letter A-I inclusive
  • (m) = the letter may be replaced with any letter from C to F, which represent the corresponding LGF levels: C = 30%, D = 35%, E = 40%, F = 45%.
  • (n) = the letter should be replaced with a number, 5 thru 10, inclusive.
  • (o) = the letter should be replaced with a number from the following set: [3, 3.1,3.2, 3.3, 3.4, 4, 4.1, 4.2, 4.3, 4.4, 5].
  • (p) = the letter should be replaced with a number, 5 - 20, inclusive.
  • (q) = the letter should be replaced with a number, 1 - 5, inclusive.
  • (+) = UL will allow up to 50% regrind in this product
  • ($) = Represents all colors except blue and green.

Copies of UL Yellow Cards for RTP Company compounds listed in this section are available via fax or postal mail upon request. Contact our Marketing Communications staff at 507-454-6900 or 800-433-4787, fax 507-454-2041, or e-mail rtp@rtpcompany.com.